TOC online analyzer
Innovative, Unique, Continuous
On-line Monitoring of Total Organic Carbon levels in Water Samples
Parameters
TOC / TC (User selectable)
IC (Optional)
TN (Optional)
COD (by correlation)
Application Areas rs
Continuous, Online monitoring of Organic Load in various environmental process applications:
Surface Water
Municipal & Sewage Wastewater
Industrial Wastewater
General Specifications
• The monitor is designed for continuous operation
• Measured parameters: TC or TOC, by operator’s selection; IC and TN are optional additions
• Instrument has dual zone high temperature combustion technology and the higher temperature zone is adjustable between 600- 1000°C
• Range is set from 0-5mg/L to 0-1,000mg/ L TOC, operator adjustable. 1000mgTOC/L is achieved without dilution of the sample
• Limit of Detection is 0.1mgC
• Measuring method: High Temperature Catalytic Oxidation (HTCO); TOC is analyzed by direct NPOC measurement, IC removal is achieved by air sparging and acidification
• Sensor for carbon analysis is nondispersive infrared detector (NDIR)
• Analysis cycle time depends on number of wash cycles, however it is arranged by the operator; nominally between 5 to 20 minutes
• Samples at 1 to 2 bar-absolute are introduced without problem, by getting use of internal sampling pump
• Air flow rate is operator adjustable and nominally about 200mL/min,
• Sample temperature of 5°C to 50°C is affordable
• Fluid flow for accurate and repeatable injection is achieved through 3 peristaltic pumps plus a 6-port solenoid driven valve
• Waste liquid disposal is achieved automatically by peristaltic pump
• Ambient temperature of between 5°C and 40°C is good for proper operation
• Communication and available digital outputs: via RS232; date and time, up to 3 measured parameters and error messages; profibus, modbus and ethernet options are available as adders
• 0-10 VDC and 4-20 mA analog output options are available for future upgrade
• 2 dry contact alarm limits are set by user
• Data storage and data presentation: up to 9999 recent results should be saved and stored, on the basis of “first in first out” method; graphical trend presentation is available on the display and initiated by the operator
• Following software functions are available:
o System diagnostics, data storage, optional single or multipoint calibration file storage; single validation cycle;
o Design of an analytical cycles as to include as many DI wash and sample wash runs as required; maintenance cycle management and warning of replacement parts based on run cycles;
o Continuous control of sample, acid and DI water flows, liquid leakage, furnace
o Temperature, air flow rate; air leakage;
o Auto-stand-by in case of: emptied acid bottle, sample-acid-DI water leakage, air leakage, furnace temperature failure;
o Graphical presentation of trend between settable date and time
• Power requirement is 230 VAC 50/60 Hz; 1200VA
• Carrier Gas: hydrocarbon and CO2 free air at 2-6 bar
• Compliance with standard methods: 5310B, EPA 415.1, ISO 8245:1999, DIN1484:1997
• A start up kit is included in the standard pack, for immediate commissioning to operate the instrument at site, for limited number of runs, however a consumables kit is recommended for a year of smooth operation
• Lifelong remote support is available
* Above are only for a common instrument, for specific instuments please refer to your orders/requirements.